← Back to IBM z/OS ACF2 Security Technical Implementation Guide

V-223470

CAT II (Medium)

IBM z/OS procedures must restrict ACF2 LOGONIDs with the READALL attribute to auditors and/or authorized users.

Rule ID

SV-223470r991589_rule

STIG

IBM z/OS ACF2 Security Technical Implementation Guide

Version

V9R8

CCIs

CCI-000366

Discussion

The use of security policy filters provides protection for the confidentiality of data by restricting the flow of data. A crucial part of any flow control solution is the ability to configure policy filters. This allows the operating system to enforce multiple and different security policies. Policy filters serve to enact and enforce the organizational policy as it pertains to controlling data flow.

Check Content

From the ACF Command line enter:
SET LID
LIST IF(READALL)

If procedures are in place to ensure logonids with the READALL attribute are used and controlled in accordance with the DISA requirements, this is not a finding.

The READALL privilege is available for actual auditing of system data. It gives the capability of looking at every data set on the system despite the data set rules. Its use is strongly discouraged. Always grant access through the use of standard data set access rules. Under no circumstances will the privilege be used as a convenience to the person maintaining the rule sets. Only use this privilege when absolutely necessary, and only give it to auditors. Remove the privilege once the audit is complete. Fully document the granting and revoking of the access.

Fix Text

Develop procedures to control Logonids with the READALL attribute.

The READALL privilege is available for actual auditing of system data. It gives the capability of looking at every data set on the system despite the data set rules. Its use is strongly discouraged. Always grant access through the use of standard data set access rules. Under no circumstances will the privilege be used as a convenience to the person maintaining the rule sets. Only use this privilege when absolutely necessary, and only give it to auditors. Remove the privilege once the audit is complete. Fully document the granting and revoking of the access.