V-268254

CAT II (Medium)

The HYCU virtual appliance must generate an immediate real-time alert of all audit failure events requiring real-time alerts.

Rule ID

SV-268254r1038704_rule

STIG

HYCU Protege Security Technical Implementation Guide

Version

V1R2

CCIs

CCI-001858CCI-003831

Discussion

It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Satisfies: SRG-APP-000360-NDM-000295, SRG-APP-000795-NDM-000130

Check Content

Log in to the HYCU Web UI and review the "Events" menu and "Email Notifications" to verify that all appropriate/relevant audit failure events are included in the "Category" drop-down menu. 

If these events are not shown (reference a recent event capturing a login to HYCU for validation), this is a finding.

Fix Text

Log in to the HYCU Web UI and go to the "Events" menu and open "Email Notifications".
 
Ensure that all the appropriate/relevant categories are selected and that the "Status" includes failures.
 
Add a "Subject" for the "Email Notifications" and email address for necessary auditors or HYCU administrators.