V-204728

CAT II (Medium)

The application server must alert the SA and ISSO, at a minimum, in the event of a log processing failure.

Rule ID

SV-204728r960912_rule

STIG

Application Server Security Requirements Guide

Version

V4R4

CCIs

CCI-000139

Discussion

Logs are essential to monitor the health of the system, investigate changes that occurred to the system, or investigate a security incident. When log processing fails, the events during the failure can be lost. To minimize the timeframe of the log failure, an alert needs to be sent to the SA and ISSO at a minimum. Log processing failures include, but are not limited to, failures in the application server log capturing mechanisms or log storage capacity being reached or exceeded. In some instances, it is preferred to send alarms to individuals rather than to an entire group. Application servers must be able to trigger an alarm and send an alert to, at a minimum, the SA and ISSO in the event there is an application server log processing failure.

Check Content

Review application server log configuration.  Verify the application server sends alerts to the SA and ISSO in the event of a log processing failure.

If the application server is not configured to meet this requirement, this is a finding.

Fix Text

Configure the application server log feature to alert the SA and ISSO in the event of a log processing failure.