V-205476

CAT II (Medium)

The Mainframe Products must use internal system clocks to generate time stamps for audit records.

Rule ID

SV-205476r960927_rule

STIG

Mainframe Product Security Requirements Guide

Version

V3R4

CCIs

CCI-000159

Discussion

Without an internal clock used as the reference for the time stored on each event to provide a trusted common reference for the time, forensic analysis would be impeded. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. If the internal clock is not used, the system may not be able to provide time stamps for log messages. Additionally, externally generated time stamps may not be accurate. Applications can use the capability of an operating system or purpose-built module for this purpose.

Check Content

Examine installation and configuration settings.

If the Mainframe Product does not use the z/OS system clock for audit time stamps, this is a finding.

Fix Text

Configure the Mainframe Product to use the z/OS system clock for audit time stamps.