V-70709

CAT II (Medium)

Navigation to URLs embedded in Office products must be blocked.

Rule ID

SV-85333r1_rule

STIG

Microsoft Project 2016 Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-001170

Discussion

To protect users from attacks, Internet Explorer usually does not attempt to load malformed URLs. This functionality can be controlled separately for instances of Internet Explorer spawned by Office applications (for example, if a user clicks a link in an Office document or selects a menu option that loads a web page). If Internet Explorer attempts to load a malformed URL, a security risk could occur.

Check Content

Verify the policy value for Computer Configuration -> Administrative Templates -> Microsoft Office 2016 (Machine) -> Security Settings -> IE Security "Navigate URL" is set to "Enabled" and 'winproj.exe' is checked.

Procedure: Use the Windows Registry Editor to navigate to the following key: 

HKLM\Software\Microsoft\Internet Explorer\Main\FeatureControl\FEATURE_VALIDATE_NAVIGATE_URL

Criteria: If the value winproj.exe is REG_DWORD = 1, this is not a finding.

Fix Text

Set the policy value for Computer Configuration -> Administrative Templates -> Microsoft Office 2016 (Machine) -> Security Settings -> IE Security "Navigate URL" to "Enabled" and place a check in the 'winproj.exe' check box.