© 2026 Beacon Cloud Solutions, Inc. All rights reserved.
← Back to Tri-Lab Operating System Stack (TOSS) 5 Security Technical Implementation Guide

V-282567

CAT II (Medium)

TOSS 5 must take appropriate action when the internal event queue is full.

Rule ID

SV-282567r1200681_rule

STIG

Tri-Lab Operating System Stack (TOSS) 5 Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-001851

Discussion

The audit system should have an action setup in the event the internal event queue becomes full so that no data is lost. Information stored in one location is vulnerable to accidental or incidental deletion or alteration. Off-loading is a common process in information systems with limited audit storage capacity.

Check Content

Verify TOSS 5 audit system is configured to take an appropriate action when the internal event queue is full:

$ sudo grep -i overflow_action /etc/audit/auditd.conf 

overflow_action = syslog

If the value of the "overflow_action" option is not set to "syslog", "single", "halt" or the line is commented out, ask the system administrator (SA) to indicate how the audit logs are off-loaded to a different system or media. If there is no evidence that the transfer of the audit logs being off-loaded to another system or media takes appropriate action if the internal event queue becomes full, this is a finding.

Fix Text

Edit the "/etc/audit/auditd.conf" file and add or update the "overflow_action" option:

overflow_action = syslog