← Back to IBM DataPower Network Device Management Security Technical Implementation Guide

V-65185

CAT II (Medium)

The DataPower Gateway must employ automated mechanisms to assist in the tracking of security incidents.

Rule ID

SV-79675r1_rule

STIG

IBM DataPower Network Device Management Security Technical Implementation Guide

Version

V1R2

CCIs

CCI-000366, CCI-000833

Discussion

Despite the investment in perimeter defense technologies, enclaves are still faced with detecting, analyzing, and remediating network breaches and exploits that have made it past the network device. An automated incident response infrastructure allows network operations to immediately react to incidents by identifying, analyzing, and mitigating any network device compromise. Incident response teams can perform root cause analysis, determine how the exploit proliferated, and identify all affected nodes, as well as contain and eliminate the threat. The network device assists in the tracking of security incidents by logging detected security events. The audit log and network device application logs capture different types of events. The audit log tracks audit events occurring on the components of the network device. The application log tracks the results of the network device content filtering function. These logs must be aggregated into a centralized server and can be used as part of the organization's security incident tracking and analysis.

Check Content

Go to Administration >> Miscellaneous >> Manage Log Targets. Verify the log target. If no log target exists, this is a finding.

Fix Text

Go to Administration >> Miscellaneous >> Manage Log Targets. Click the log target or add one. Go to the Event Subscriptions tab and click on the event categories that are required to be audited.