← Back to Microsoft IIS 10.0 Site Security Technical Implementation Guide

V-218762

CAT II (Medium)

The Idle Time-out monitor for each IIS 10.0 website must be enabled.

Rule ID

SV-218762r1192782_rule

STIG

Microsoft IIS 10.0 Site Security Technical Implementation Guide

Version

V2R15

CCIs

CCI-002361

Discussion

The idle time-out attribute controls the amount of time a worker process will remain idle before it shuts down. A worker process is idle if it is not processing requests and no new requests are received. The purpose of this attribute is to conserve system resources; the default value for idle time-out is 20 minutes. By default, the World Wide Web (WWW) service establishes an overlapped recycle, in which the worker process to be shut down is kept running until after a new worker process is started.

Check Content

Note: If the IIS 10.0 installation is supporting Microsoft Exchange, WSUS, or SharePoint and is not otherwise hosting any content, this requirement is not applicable.

Follow the procedures below for each site hosted on the IIS 10.0 web server:

Open the IIS 10.0 Manager.

Click the Application Pools.

Highlight an Application Pool to review and click "Advanced Settings" in the "Actions" pane.

Scroll down to the "Process Model" section and verify the value for "Idle Time-out" is not "0".

If the "Idle Time-out" is set to "0", this is a finding.

Fix Text

Follow the procedures below for each site hosted on the IIS 10.0 web server:

Open the IIS 10.0 Manager.

Click the Application Pools.

Highlight an Application Pool to review and click "Advanced Settings" in the "Actions" pane.

Scroll down to the "Process Model" section and set the value for "Idle Time-out" to something other than "0". "20" or less is recommended if the amount of RAM on the system is limited.