V-246938

CAT II (Medium)

ONTAP must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Rule ID

SV-246938r961443_rule

STIG

NetApp ONTAP DSC 9.x Security Technical Implementation Guide

Version

V2R3

CCIs

CCI-001890

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.

Check Content

Use "cluster date show" to see the current time zone configured.

If ONTAP is not configured to record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT), this is a finding.

Fix Text

Configure the time zone to UTC with "cluster date modify -timezone UTC".