V-234622

CAT II (Medium)

The UEM server must be configured with the periodicity of the following commands to the agent of six hours or less: - query connectivity status - query the current version of the managed device firmware/software - query the current version of installed mobile applications - read audit logs kept by the managed device.

Rule ID

SV-234622r961731_rule

STIG

Unified Endpoint Management Server Security Requirements Guide

Version

V2R4

CCIs

CCI-002696

Discussion

Without verification, security functions may not operate correctly and this failure may go unnoticed. Security function is defined as the hardware, software, and/or firmware of the information system responsible for enforcing the system security policy and supporting the isolation of code and data on which the protection is based. Security functionality includes, but is not limited to, establishing system accounts, configuring access authorizations (i.e., permissions, privileges), setting events to be audited, and setting intrusion detection parameters. This requirement applies to applications performing security functions and the applications performing security function verification/testing. Satisfies:FAU_NET_EXT.1.1, FMT_SMF.1.1(2) c.3 Reference:PP-MDM-411057

Check Content

Verify the UEM server is configured with the periodicity of the following commands to the agent of six hours or less: 
- query connectivity status;
- query the current version of the managed device firmware/software;
- query the current version of installed mobile applications;
- read audit logs kept by the managed device.

If the UEM server is not configured with the periodicity of the following commands to the agent of six hours or less: 
- query connectivity status;
- query the current version of the managed device firmware/software;
- query the current version of installed mobile applications;
- read audit logs kept by the managed device,
this is a finding.

Fix Text

Configure the UEM server with the periodicity of the following commands to the agent of six hours or less: 
- query connectivity status;
- query the current version of the managed device firmware/software;
- query the current version of installed mobile applications;
- read audit logs kept by the managed device.