← Back to VMware vSphere 7.0 Virtual Machine Security Technical Implementation Guide

V-256457

CAT II (Medium)

Unauthorized floppy devices must be disconnected on the virtual machine (VM).

Rule ID

SV-256457r959010_rule

STIG

VMware vSphere 7.0 Virtual Machine Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-000366

Discussion

Ensure no device is connected to a virtual machine if it is not required. For example, floppy, serial, and parallel ports are rarely used for virtual machines in a data center environment, and CD/DVD drives are usually connected only temporarily during software installation.

Check Content

Floppy drives are no longer visible through the vSphere Client and must be done via the Application Programming Interface (API) or PowerCLI.

From a PowerCLI command prompt while connected to the ESXi host or vCenter server, run the following command:

Get-VM | Get-FloppyDrive | Select Parent, Name, ConnectionState

If a virtual machine has a floppy drive connected, this is a finding.

Fix Text

Floppy drives are no longer visible through the vSphere Client and must be done via the API or PowerCLI.

From a PowerCLI command prompt while connected to the ESXi host or vCenter server, run the following command:

Get-VM "VM Name" | Get-FloppyDrive | Remove-FloppyDrive