V-250998

CAT III (Low)

Sentry must generate an immediate real-time alert of all audit failure events requiring real-time alerts.

Rule ID

SV-250998r1028236_rule

STIG

Ivanti Sentry 9.x NDM Security Technical Implementation Guide

Version

V3R1

CCIs

CCI-001858

Discussion

It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.

Check Content

Verify the Sentry is configured to send alerts for failure events in Sentry System Manager web GUI. 

1. Log in to Sentry.
2. Go to Monitoring >> Alert Configuration.
3. Verify Alert monitoring is configured.

If Alert Configuration settings are not configured, this is a finding. 

Refer to the "Alert Configuration" section of the "Sentry 9.8.0 Guide for MobileIron Core" for more information.

Fix Text

Configure the Sentry to send alerts for failure events in Sentry System Manager web GUI. 

1. Log in to Sentry.
2. Go to Monitoring >> Alert Configuration.
3. Check "Send Notification".
4. Apply Email List.
5. Enter Alerts Per Hour.
6. Enter Batch Time Interval (min).
7. Select "Default Alert Action".
8. Apply.
9. Add Alert Notification Management.
10. Add Alert ID.
11. Add "Action" from dropdown.
12. Click "Apply" and "Save" in the top right corner.