V-217371

CAT II (Medium)

The Arista Multilayer Switch must generate audit records for privileged activities or other system-level access.

Rule ID

SV-217371r961827_rule

STIG

Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-000172

Discussion

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one. Audit records can be generated from various components within the information system (e.g., module or policy filter).

Check Content

Determine if the network device generates audit records for privileged activities or other system-level access. 

If the network device does not generate audit records for privileged activities or other system-level access, this is a finding.

Verify logging is configured to audit full-text commands.

Execute a "show logging" command and review the logs to verify the full text of commands is included.

Fix Text

Configure the network device to generate audit records for privileged activities or other system-level access.

aaa accounting commands all default start-stop
aaa accounting exec default start-stop
aaa accounting system default start-stop