STIGhubSTIGhub
STIGsSearchCompare

STIGhub

A free tool to search and browse the entire DISA STIG library. Saves up to 75% in security compliance research time.

Navigation

  • Browse STIGs
  • Search
  • Compare Versions

Resources

  • About
  • Release Notes
  • VPAT
  • DISA STIG Library
STIGs updated 3 hours ago
Powered by Pylon
© 2026 Beacon Cloud Solutions, Inc. All rights reserved.
← Back to HP FlexFabric Switch NDM Security Technical Implementation Guide

V-217464

CAT II (Medium)

The HP FlexFabric Switch must generate an immediate real-time alert of all audit failure events requiring real-time alerts.

Rule ID

SV-217464r961401_rule

STIG

HP FlexFabric Switch NDM Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-001858

Discussion

It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).

Check Content

Determine if the HP FlexFabric Switch provides the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time.

[HP] display info-center

Information Center: Enabled
Console: Enabled
Monitor: Enabled
Log host: Enabled
    192.100.50.27,
    port number: 514, host facility: local7
Log buffer: Enabled
    Max buffer size 1024, current buffer size 512
    Current messages 66, dropped messages 0, overwritten messages 0
Log file: Enabled
Security log file: Enabled
Information timestamp format:
    Log host: Date
    Other output destination: Date

If the HP FlexFabric Switch does not provide the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time, this is a finding.

Fix Text

Configure the HP FlexFabric Switch to generate an immediate real-time alert of all audit failure events requiring real-time alerts.

[HP] info-center enable