← Back to Fortinet FortiGate Firewall NDM Security Technical Implementation Guide

V-234176

CAT II (Medium)

The FortiGate device must generate audit records showing starting and ending time for administrator access to the system.

Rule ID

SV-234176r961830_rule

STIG

Fortinet FortiGate Firewall NDM Security Technical Implementation Guide

Version

V1R5

CCIs

CCI-000172

Discussion

Without generating audit records specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one. Audit records can be generated from various components within the network device (e.g., module or policy filter).

Check Content

Log in to the FortiGate GUI with Super-Admin privilege.

1. Open a CLI console, via SSH or available from the GUI.
2. Run the following command:
     # show full-configuration log eventfilter | grep -i 'event\|system'

The output should be:   
          set event enable
          set system enable

If the event and system parameters are set to disable, this is a finding.

Fix Text

When Event Logging is enabled the device will audit starting and ending time for administrator access to the system. To enable event logging, log in to the FortiGate GUI with Super-Admin privilege.

1. Open a CLI console, via SSH or available from the GUI.
2. Run the following command:

     # config log eventfilter
     #    set event enable
     #    set system enable
     # end