V-217368

CAT II (Medium)

The Arista Multilayer Switch must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Rule ID

SV-217368r961443_rule

STIG

Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-001890

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.

Check Content

Determine if the network device records time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT). This requirement may be verified by demonstration or configuration review.

If the network device does not record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT), this is a finding.

This can be configured with the following command:

clock timezone GMT

and verified by 

show run section clock

Log records can be validated with:

show logging

Fix Text

Configure the network device to record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

This can be configured with the following command:

clock timezone GMT