V-237054

CAT II (Medium)

The A10 Networks ADC must enable logging for packet anomaly events.

Rule ID

SV-237054r971533_rule

STIG

A10 Networks ADC ALG Security Technical Implementation Guide

Version

V2R2

CCIs

CCI-002664

Discussion

Without an alert, security personnel may be unaware of major detection incidents that require immediate action and this delay may result in the loss or compromise of information. Since these incidents require immediate action, these messages are assigned a critical or level 1 priority/severity, depending on the system's priority schema. These systems must generate an alert when detection events from real-time monitoring occur. Alerts may be transmitted, for example, telephonically, by electronic mail messages, or by text messaging. The device must either send the alert to a management console that is actively monitored by authorized personnel or use a messaging capability to send the alert directly to designated personnel. The A10 Networks ADC must be configured to generate a log message when IP anomalies are detected.

Check Content

Review the device configuration.

The following command displays the device configuration and filters the output on the string "log":
show run | inc log

If the output does not include the command "system anomaly log", this is a finding.

Fix Text

The following command enables logging of packet anomaly events:
system anomaly log