STIGhubSTIGhub
STIGsSearchCompare

STIGhub

A free tool to search and browse the entire DISA STIG library. Saves up to 75% in security compliance research time.

Navigation

  • Browse STIGs
  • Search
  • Compare Versions

Resources

  • About
  • Release Notes
  • VPAT
  • DISA STIG Library
STIGs updated 5 hours ago
Powered by Pylon
© 2026 Beacon Cloud Solutions, Inc. All rights reserved.
← Back to CA IDMS Security Technical Implementation Guide

V-251647

CAT II (Medium)

The storage used for data collection by CA IDMS web services must be protected.

Rule ID

SV-251647r961638_rule

STIG

CA IDMS Security Technical Implementation Guide

Version

V2R1

CCIs

CCI-002420, CCI-002422

Discussion

Information can be either unintentionally or maliciously disclosed or modified during preparation for transmission, including, for example, during aggregation, at protocol transformation points, and during packing/unpacking. These unauthorized disclosures or modifications compromise the confidentiality or integrity of the information. Use of this requirement will be limited to situations where the data owner has a strict requirement for ensuring data integrity and confidentiality is maintained at every step of the data transfer and handling process. When transmitting data, the DBMS, associated applications, and infrastructure must leverage transmission protection mechanisms. Satisfies: SRG-APP-000441-DB-000378, SRG-APP-000442-DB-000379

Check Content

Log on to IDMS DC system and issue "DCPROFIL". If SYSTEM STORAGE PROTECTED: display is "NO", this is a finding. 

Issue DCMT D PROGRAM RHDCWSSP. If Storage Prot is "NO", this is a finding.

Fix Text

Use the following system generation parameters to enable the use of standard storage protection: 

Set STORAGE KEY parameter of the SYSTEM statement to a value that is not "9". (The value other than 9 is dependent on how the z/OS parm AllowUserKeyCSA is set).

Set PROTECT/NOPROTECT parameter of the SYSTEM statement to "PROTECT".

Set PROTECT/NOPROTECT parameter of the PROGRAM statement to "PROTECT" for RHDCWSSP.

Generate and restart the system.