← Back to Mainframe Product Security Requirements Guide

V-205613

CAT II (Medium)

The Mainframe Product must generate audit records showing starting and ending time for user access to the system.

Rule ID

SV-205613r961830_rule

STIG

Mainframe Product Security Requirements Guide

Version

V3R4

CCIs

CCI-000172

Discussion

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident, or identify those responsible for one. Audit records can be generated from various components within the information system (e.g., module or policy filter).

Check Content

If the Mainframe Product has no function or capability for user access this is not applicable.

Examine configuration settings. 

If the Mainframe Product does not identify and audit start and end times of access to the systems, this is a finding.

Fix Text

Configure the Mainframe Product to provide audit SAF call for starting and ending time for user access to the system.