STIGhubSTIGhub
STIGsRMF ControlsCompare

STIGhub

A free tool to search and browse the entire DISA STIG library. Saves up to 75% in security compliance research time.

Navigation

  • Browse STIGs
  • Search
  • RMF Controls
  • Compare Versions

Resources

  • About
  • Release Notes
  • VPAT
  • DISA STIG Library
STIGs updated 4 hours ago
Powered by Pylon
© 2026 Beacon Cloud Solutions, Inc. All rights reserved.
← Back to RUCKUS ICX NDM Security Technical Implementation Guide

V-273821

CAT II (Medium)

The RUCKUS ICX device must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Rule ID

SV-273821r1111025_rule

STIG

RUCKUS ICX NDM Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-001890

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of GMT, or local time with an offset from UTC.

Check Content

Verify a time zone is configured on the device:

SSH@ICX# show clock
15:13:51.679 GMT+00 Mon Jan 15 2024

If the time does not reflect a time zone that can be mapped to GMT, this is a finding.

Fix Text

Configure a time zone as needed:

SSH@ICX(config) clock timezone [timezone]