← Back to Cisco NX OS Switch NDM Security Technical Implementation Guide

V-220498

CAT II (Medium)

The Cisco switch must be configured to synchronize its clock with the primary and secondary time sources using redundant authoritative time sources.

Rule ID

SV-220498r1026071_rule

STIG

Cisco NX OS Switch NDM Security Technical Implementation Guide

Version

V3R6

CCIs

CCI-004928, CCI-004922, CCI-004923

Discussion

The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891. DOD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DOD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source.

Check Content

Review the Cisco switch configuration to verify it is compliant with this requirement as shown in the configuration example below:

ntp server 10.1.12.10
ntp server 10.1.22.13

If the Cisco switch is not configured to synchronize its clock with redundant authoritative time sources, this is a finding.

Fix Text

Configure the Cisco switch to synchronize its clock with redundant authoritative time sources as shown in the example below:

SW1(config)# feature ntp
SW1(config)# ntp server 10.1.12.10
SW1(config)# ntp server 10.1.22.13
SW1(config)# end