← Back to Honeywell Android 9.x COPE Security Technical Implementation Guide

V-235090

CAT II (Medium)

Honeywell Mobility Edge Android Pie devices must be configured to disallow configuration of date and time.

Rule ID

SV-235090r626531_rule

STIG

Honeywell Android 9.x COPE Security Technical Implementation Guide

Version

V1R2

CCIs

CCI-000366

Discussion

Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events. Periodically synchronizing internal clocks with an authoritative time source is necessary to correctly correlate the timing of events that occur across the enterprise. The three authoritative time sources for Honeywell Mobility Edge Android Pie devices are an authoritative time server that is synchronized with redundant United States Naval Observatory (USNO) time servers as designated for the appropriate DoD network (NIPRNet or SIPRNet), or the Global Positioning System (GPS), or the wireless carrier. Time stamps generated by the audit system in Honeywell Mobility Edge Android Pie devices must include both date and time. The time may be expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. SFR ID: FMT_SMF_EXT.1.1 #47

Check Content

Review the Honeywell Android Pie device's Work Profile configuration settings to confirm that autofill services are disabled. 
 
This procedure is performed on both the MDM Administration console and the Honeywell Android Pie device. 
 
On the MDM console, verify that "Set auto (network) time required" is set to "On".
 
On the Honeywell Android Pie device: 
1. Open Settings. 
2. Tap "System". 
3. Tap "Date & times". 
4. Verify that "Automatic date & time" is grayed out.
 
If on the MDM console "Set auto (network) time required" is not set to "On", or on the Honeywell Android Pie device "Automatic date & time" is grayed out, this is a finding.

Fix Text

Configure the Honeywell Android Pie device's Work Profile to set auto network time.
 
On the MDM console, in the Android user restrictions section, set "Set auto (network) time required" to "On".