← Back to Application Layer Gateway Security Requirements Guide

V-204967

CAT II (Medium)

The ALG providing content filtering must send an immediate (within seconds) alert to the system administrator, at a minimum, in response to malicious code detection.

Rule ID

SV-204967r396036_rule

STIG

Application Layer Gateway Security Requirements Guide

Version

V2R3

CCIs

CCI-001243

Discussion

Without an alert, security personnel may be unaware of an impending failure of the audit capability; then the ability to perform forensic analysis and detect rate-based and other anomalies will be impeded. The ALG generates an immediate (within seconds) alert which notifies designated personnel of the incident. Sending a message to an unattended log or console does not meet this requirement since that will not be seen immediately. These messages should include a severity level indicator or code as an indicator of the criticality of the incident.

Check Content

If the ALG does not perform content filtering as part of the traffic management functionality, this is not applicable.

Verify the ALG sends an immediate (within seconds) alert to the system administrator, at a minimum, when malicious code is detected.

If the ALG does not send an immediate (within seconds) alert to the system administrator, at a minimum, when malicious code is detected, this is a finding.

Fix Text

If the ALG performs content filtering as part of the traffic management functionality, configure the ALG to send an immediate (within seconds) alert to the system administrator, at a minimum, when malicious code is detected.