← Back to Central Log Server Security Requirements Guide

V-206502

CAT III (Low)

The Central Log Server must be configured to perform audit reduction that does not alter original content or time ordering of log records.

Rule ID

SV-206502r961428_rule

STIG

Central Log Server Security Requirements Guide

Version

V3R4

CCIs

CCI-001881

Discussion

If the audit reduction capability alters the content or time ordering of log records, the integrity of the log records is compromised, and the records are no longer usable for forensic analysis. Time ordering refers to the chronological organization of records based on time stamps. The degree of time stamp precision can affect this. Audit reduction is a process that manipulates collected audit information and organizes such information in a summary format that is more meaningful to analysts. This requirement is specific to applications with audit reduction capabilities; however, applications need to support on-demand audit review and analysis.

Check Content

Examine the configuration.

Verify the Central Log Server performs audit reduction that does not alter original content or time ordering of log records.

If the Central Log Server is not configured to perform audit reduction that does not alter original content or time ordering of log records, this is a finding.

Fix Text

Configure the Central Log Server to perform audit reduction that does not alter original content or time ordering of log records.