← Back to HP FlexFabric Switch L2S Security Technical Implementation Guide

V-66065

CAT II (Medium)

The HP FlexFabric Switch must have BPDU Guard enabled on all user-facing access ports.

Rule ID

SV-80555r1_rule

STIG

HP FlexFabric Switch L2S Security Technical Implementation Guide

Version

V1R3

CCIs

CCI-002385

Discussion

If a rogue switch is introduced into the topology and transmits a Bridge Protocol Data Unit (BPDU) with a lower bridge priority than the existing root bridge, it will become the new root bridge and cause a topology change, rendering the network in a suboptimal state. The Spanning Tree Protocol (STP) PortFast BPDU guard enhancement allows network designers to enforce the STP domain borders and keep the active topology predictable. The devices behind the ports that have STP PortFast enabled are not able to influence the STP topology. At the reception of BPDUs, the BPDU guard operation disables the port that has PortFast configured. The BPDU guard transitions the port into errdisable state and sends a log message.

Check Content

Review the HP FlexFabric Switch configuration to verify that BPDU Protection is enabled on all user-facing switch ports.

If the HP FlexFabric Switch has not enabled BPDU protection, this is a finding.

[HP] display stp
-------[CIST Global Info][Mode MSTP]-------
 Bridge ID           : 32768.7848-596a-6580
 Bridge times        : Hello 2s MaxAge 20s FwdDelay 15s MaxHops 20
 Root ID/ERPC        : 32768.7848-596a-6580, 0
 RegRoot ID/IRPC     : 32768.7848-596a-6580, 0
 RootPort ID         : 0.0
 BPDU-Protection     : Enabled
 Bridge Config-
 Digest-Snooping     : Disabled
 TC or TCN received  : 0
 Time since last TC  : 3 days 

interface GigabitEthernet1/0/1
 stp edged-port

Fix Text

Configure the HP FlexFabric Switch to have BPDU Guard enabled on all user-facing switch ports.

[HP]stp bpdu-protection
[HP-GigabitEthernet1/0/1]stp edged-port