V-228994

CAT II (Medium)

The BIG-IP appliance must be configured to activate a system alert message, send an alarm, and/or automatically shut down when a component failure is detected.

Rule ID

SV-228994r961863_rule

STIG

F5 BIG-IP Device Management Security Technical Implementation Guide

Version

V2R4

CCIs

CCI-000366CCI-001328

Discussion

Predictable failure prevention requires organizational planning to address device failure issues. If components key to maintaining the device's security fail to function, the device could continue operating in an unsecure state. If appropriate actions are not taken when a network device failure occurs, a denial of service condition may occur that could result in mission failure since the network would be operating without a critical security monitoring and prevention function. Upon detecting a failure of network device security components, the network device must activate a system alert message, send an alarm, or shut down.

Check Content

Verify the BIG-IP appliance is configured to activate a system alert message, send an alarm, and/or automatically shut down when a component failure is detected. 

Navigate to the BIG-IP System manager >> Logs >> Configuration >> Options.

Verify that "MCP" under the "Audit Logging" section is set to Debug.

Navigate to the BIG-IP System manager >> System >> High Availability >> Fail-Safe >> System.

Verify "Switch Board Failure" under the "System Trigger Properties" section is set to perform the appropriate action based on the location of the device. 

If the BIG-IP appliance is not configured to activate a system alert message, send an alarm, or automatically shut down when a component failure is detected, this is a finding.

Fix Text

Configure the BIG-IP appliance to activate a system alert message, send an alarm, and/or automatically shut down when a component failure is detected.