STIGhubSTIGhub
STIGsSearchCompare

STIGhub

A free tool to search and browse the entire DISA STIG library. Saves up to 75% in security compliance research time.

Navigation

  • Browse STIGs
  • Search
  • Compare Versions

Resources

  • About
  • Release Notes
  • VPAT
  • DISA STIG Library
STIGs updated 3 hours ago
Powered by Pylon
© 2026 Beacon Cloud Solutions, Inc. All rights reserved.
← Back to VMware vSphere 8.0 Virtual Machine Security Technical Implementation Guide

V-258722

CAT II (Medium)

Virtual machines (VMs) must remove unneeded floppy devices.

Rule ID

SV-258722r933227_rule

STIG

VMware vSphere 8.0 Virtual Machine Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-000366

Discussion

Ensure no device is connected to a virtual machine if it is not required. For example, floppy, serial, and parallel ports are rarely used for virtual machines in a data center environment, and CD/DVD drives are usually connected only temporarily during software installation.

Check Content

Floppy drives are no longer visible through the vSphere Client and must be done via the Application Programming Interface (API) or PowerCLI.

From a PowerCLI command prompt while connected to the ESXi host or vCenter server, run the following command:

Get-VM | Get-FloppyDrive | Select Parent, Name, ConnectionState

If a virtual machine has a floppy drive connected, this is a finding.

Fix Text

Floppy drives are no longer visible through the vSphere Client and must be done via the Application Programming Interface (API) or PowerCLI.

The VM must be powered off to remove a floppy drive.

From a PowerCLI command prompt while connected to the ESXi host or vCenter server, run the following command:

Get-VM "VM Name" | Get-FloppyDrive | Remove-FloppyDrive