V-217446

CAT III (Low)

The HP FlexFabric Switch must generate audit records containing the full-text recording of privileged commands.

Rule ID

SV-217446r960909_rule

STIG

HP FlexFabric Switch NDM Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-000135

Discussion

Reconstruction of harmful events or forensic analysis is not possible if audit records do not contain enough information. Organizations consider limiting the additional audit information to only that information explicitly needed for specific audit requirements. The additional information required is dependent on the type of information (i.e., sensitivity of the data and the environment within which it resides). At a minimum, the organization must audit full-text recording of privileged commands. The organization must maintain audit trails in sufficient detail to reconstruct events to determine the cause and impact of compromise.

Check Content

Determine if the info-center feature is enabled on the HP FlexFabric Switch:

[HP] display info-center

Information Center: Enabled

If logging is not enabled, this is a finding.

Fix Text

Enable info-center feature on the HP FlexFabric Switch:

[HP] info-center enable