Rule ID
SV-234391r1035568_rule
Version
V2R4
CCIs
Without confidentiality protection mechanisms, unauthorized individuals may gain access to sensitive information via a remote access session. Nonlocal maintenance and diagnostic activities are activities conducted by individuals communicating through either an external network (e.g., the internet) or an internal network. Satisfies: FTP_TRP.1.1(1) Refinement
Verify the UEM server invokes either host-OS functionality or server functionality to provide a trusted communication channel between itself and remote administrators that provides assured identification of its endpoints and protection of the communicated data from modification and disclosure using [selection: -IPsec, -SSH, -TLS, -HTTPS]. If the UEM server does not invoke either host-OS functionality or server functionality to provide a trusted communication channel between itself and remote administrators that provides assured identification of its endpoints and protection of the communicated data from modification and disclosure using [selection: -IPsec, -SSH, -TLS, -HTTPS], this is a finding.
Configure the UEM server to invoke either host-OS functionality or server functionality to provide a trusted communication channel between itself and remote administrators that provides assured identification of its endpoints and protection of the communicated data from modification and disclosure using [selection: -IPsec, -SSH, -TLS, -HTTPS].