V-65281

CAT II (Medium)

The DataPower Gateway must behave in a predictable and documented manner that reflects organizational and system objectives when invalid inputs are received.

Rule ID

SV-79771r1_rule

STIG

IBM DataPower ALG Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-002754

Discussion

A common vulnerability of network elements is unpredictable behavior when invalid inputs are received. This requirement guards against adverse or unintended system behavior caused by invalid inputs, where information system responses to the invalid input may be disruptive or cause the system to fail into an unsafe state. The behavior will be derived from the organizational and system requirements and includes, but is not limited to, notification of the appropriate personnel, creating an audit record, and rejecting invalid input. This requirement applies to gateways and firewalls that perform content inspection or have higher-layer proxy functions.

Check Content

Using the WebGUI, go to Objects >> XML Processing >> Matching Rule to verify there is a rule that defines the expected form of the incoming message. If there is no match, the message will be discarded. 

Go to Objects >> XML Processing >> Processing Rule to verify there are error rules that provide appropriate system responses to invalid and unexpected inputs.

If no error rules discarding invalid messages are configured, this is a finding.

Fix Text

Using the WebGUI, go to Objects >> XML Processing >> Matching Rule to define a rule that defines the expected form of the incoming message. If there is no match, the message will be discarded. 

Go to Objects >> XML Processing >> Processing Rule to define error rules that provide appropriate system responses to invalid and unexpected inputs. Invalid messages must be discarded.