← Back to Arista MLS DCS-7000 Series RTR Security Technical Implementation Guide

V-217499

CAT II (Medium)

The Arista Multilayer Switch must be configured to disable non-essential capabilities.

Rule ID

SV-217499r382903_rule

STIG

Arista MLS DCS-7000 Series RTR Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-000381

Discussion

A compromised router introduces risk to the entire network infrastructure as well as data resources that are accessible via the network. The perimeter defense has no oversight or control of attacks by malicious users within the network. Preventing network breaches from within is dependent on implementing a comprehensive defense-in-depth strategy, including securing each device connected to the network. This is accomplished by following and implementing all security guidance applicable for each node type. A fundamental step in securing each router is to enable only the capabilities required for operation.

Check Content

Review the router configuration to determine if services or functions not required for operation, or not related to router functionality (e.g., DNS, email client or server, FTP server, or web server) are enabled.

If unnecessary services and functions are enabled on the router, this is a finding.

Fix Text

Remove unneeded services and functions from the router. Removal is recommended since the service or function may be inadvertently enabled otherwise. However, if removal is not possible, disable the service or function.