Rule ID
SV-221282r960762_rule
Version
V2R3
CCIs
Data exchanged between the user and the web server can range from static display data to credentials used to log into the hosted application. Even when data appears to be static, the non-displayed logic in a web page may expose business logic or trusted system relationships. The integrity of all the data being exchanged between the user and web server must always be trusted. To protect the integrity and trust, encryption methods should be used to protect the complete communication session.
1. As required, open $DOMAIN_HOME/config/fmwconfig/components/OHS/<componentName>/ssl.conf with an editor. 2. Search for the "SSLFIPS" directive at the OHS server configuration scope. 3. If the directive is omitted or is not set to "On", this is a finding.
1. Open $DOMAIN_HOME/config/fmwconfig/components/OHS/<componentName>/ssl.conf with an editor. 2. Search for the "SSLFIPS" directive at the OHS server configuration scope. 3. Set the "SSLFIPS" directive to "On", add the directive if it does not exist.