V-94673

CAT II (Medium)

Symantec ProxySG must be configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources.

Rule ID

SV-104503r1_rule

STIG

Symantec ProxySG NDM Security Technical Implementation Guide

Version

V1R2

CCIs

CCI-000366CCI-001893

Discussion

The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891. DoD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DoD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source.

Check Content

Verify the Symantec ProxySG is configured to use authoritative NTP servers.

1. Log on to the Web Management Console.
2. Click Configuration >> General >> Clock.
3. Click "NTP", and confirm that the desired authoritative time servers are present.

If Symantec ProxySG does not be configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources, this is a finding.

Fix Text

Configure the ProxySG is configured to use authoritative NTP servers.

1. Log on to the Web Management Console.
2. Click Configuration >> General >> Clock.
3. Click "NTP", click "New", click "Add" and enter each desired authoritative time server.
4. Click "Apply".