Rule ID
SV-206504r961443_rule
Version
V3R4
CCIs
CCI-001890
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
Examine the log records stored on the events server. Verify the Central Log Server records time stamps of the time the record was received from the host or device. Verify the time stamp is mapped to UTC. If the Central Log Server is not configured to record time stamps of the time the record was received or the time stamp is not mapped to UTC, this is a finding.
Configure the Central Log Server to record time stamps of the time the record was received from the host or device. Verify the time stamp is mapped to UTC.