← Back to HP FlexFabric Switch NDM Security Technical Implementation Guide

V-217463

CAT II (Medium)

The HP FlexFabric Switch must allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.

Rule ID

SV-217463r961392_rule

STIG

HP FlexFabric Switch NDM Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-001849

Discussion

In order to ensure network devices have a sufficient storage capacity in which to write the audit logs, they need to be able to allocate audit record storage capacity. The task of allocating audit record storage capacity is usually performed during initial device setup if it is modifiable. The value for the organization-defined audit record storage requirement will depend on the amount of storage available on the HP FlexFabric Switch, the anticipated volume of logs, the frequency of transfer from the HP FlexFabric Switch to centralized log servers, and other factors.

Check Content

Enter the command display logfile summary to verify audit record storage has been allocated in accordance with the organization-defined audit record storage requirements.

If the switch has not been configured to allocate audit record storage in accordance with the organization-defined audit record storage requirements, this is a finding.

Fix Text

Configure the HP FlexFabric Switch to allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.

[HP] info-center security-logfile size-quota 10

Note: The security logfile size in set in MB