V-273696

CAT II (Medium)

The RUCKUS ICX switch must implement physically or logically separate subnetworks to isolate organization-defined critical system components and functions.

Rule ID

SV-273696r1110998_rule

STIG

RUCKUS ICX Layer 2 Switch Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-004891CCI-004931

Discussion

Separating critical system components and functions from other noncritical system components and functions through separate subnetworks may be necessary to reduce susceptibility to a catastrophic or debilitating breach or compromise that results in system failure. For example, physically separating the command and control function from the in-flight entertainment function through separate subnetworks in a commercial aircraft provides an increased level of assurance in the trustworthiness of critical system functions. Satisfies: SRG-NET-000715-L2S-000120, SRG-NET-000760-L2S-000160

Check Content

Review the RUCKUS ICX switch configuration.

Router# Show Vlans
PORT-VLAN 5, Name Organization_A, Priority level0, in single spanning tree domain
 Untagged Ports: None       2  
   Tagged Ports: (U1/M1)    4   6   8   10  12  14 
 Mac-Vlan Ports: None
     Monitoring: Disabled
PORT-VLAN 10, Name Organization_B, Priority level0, in single spanning tree domain
 Untagged Ports: None     20 21 22
   Tagged Ports: (U1/M1)   1   3   5   7   9  11 
 Mac-Vlan Ports: None
     Monitoring: Disabled                                         
PORT-VLAN 12, Name IP_Phone, Priority level0, in single spanning tree domain
 Untagged Ports: None
   Tagged Ports: (U1/M1)  30  31  32  33  34  35 
 Mac-Vlan Ports: None
     Monitoring: Disabled

If the RUCKUS ICX switch is not configured to implement physically or logically separate subnetworks to isolate organization-defined critical system components and functions, this is a finding.

Fix Text

Configure the layer 2 switch to implement physically or logically separate subnetworks to isolate organization-defined critical system components and functions.

1. Add appropriate VLAN by name.
device# configure terminal
Router(config)#vlan 5 Name Organization_A
Router(config)#vlan 10 Name Organization_B
Router(config)#vlan 10 Name IP_Phone

2. Add untagged Ports for the specific ports to the VLANs as needed.
Router(config-vlan-5)#untag ethernet 1/1/2 

3. Add tagged ports.
Router(config-vlan-5)#tag ethernet 1/1/4

4. Save the configuration.
Router(config-vlan-5)#write memory