V-217360

CAT II (Medium)

The Arista Multilayer Switch must display the Standard Mandatory DoD Notice and Consent Banner before granting access to the device.

Rule ID

SV-217360r960843_rule

STIG

Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-000048

Discussion

Display of the DoD-approved use notification before granting access to the network device ensures privacy and security notification verbiage used is consistent with applicable federal laws, Executive Orders, directives, policies, regulations, standards, and guidance. System use notifications are required only for access via logon interfaces with human users.

Check Content

Review the device configuration and verify display of the Standard DoD Notice and Consent Banner.

If the banner is not displayed, this is a finding.

To verify the device is configured to display the DoD Banner, review the running configuration with the "show running-config" command. Identify the section "banner login" and verify the standard DoD Banner is displayed.

Fix Text

Configure the switch to display the Standard DoD Notice and Consent banner.

To configure the banner, enter the following commands from the configuration mode interface. Replace the bracketed data with the DoD Banner.

switch(config)#banner login
[DoD Banner]