STIGhubSTIGhub
STIGsRMF ControlsCompare

STIGhub

A free tool to search and browse the entire DISA STIG library. Saves up to 75% in security compliance research time.

Navigation

  • Browse STIGs
  • Search
  • RMF Controls
  • Compare Versions

Resources

  • About
  • Release Notes
  • VPAT
  • DISA STIG Library
STIGs updated 1 hour ago
Powered by Pylon
© 2026 Beacon Cloud Solutions, Inc. All rights reserved.
← Back to IBM Hardware Management Console (HMC) Security Technical Implementation Guide

V-256866

CAT II (Medium)

On Classified Systems the Processor Resource/Systems Manager (PR/SM) must not allow access to system complex data.

Rule ID

SV-256866r958472_rule

STIG

IBM Hardware Management Console (HMC) Security Technical Implementation Guide

Version

V2R1

CCIs

CCI-000213

Discussion

Allowing unrestricted access to all Logical Partition data could result in the possibility of unauthorized access and updating of data. This could also impact the integrity of the processing environment.

Check Content

Have the Systems Administrator or Systems Programmer use the Hardware Management Console; to verify that the classified Logical Partition system data cannot be viewed by other Logical Partitions. 

Use the Security Definitions Panel to do this.  The Global Performance Data Control option must be turned off.

NOTE:	The default is that the Global Performance Data Control option is turned off.

If  the PR/SM allows access to system complex data then, this is a FINDING.

Fix Text

Have the Systems Administrator or Systems Programmer use the Hardware Management Console, to verify that the classified Logical Partition system data cannot be viewed by other Logical Partitions. 

Use the Security Definitions Panel to do this.  The Global Performance Data Control option must be turned off.