V-206735

CAT II (Medium)

The SDN Controller must be configured to notify the forwarding device to either drop the packet or make an entry in the flow table for a received packet that does not match any flow table entries.

Rule ID

SV-206735r385561_rule

STIG

SDN Controller Security Requirements Guide

Version

V2R2

CCIs

CCI-000366

Discussion

Reactive flow setup occurs when the SDN-aware switch receives a packet that does not match the flow table entries and hence the switch has to send the packet to the controller for processing. Once the controller decides how to process the flow that information is cached on the SDN-aware switch, and the SDN controller determines how long to keep the cache alive. In order to prevent packets from being dropped as a result of no flow table entry, it is imperative that the SDN Controller is configured to enable reactive flow setup.

Check Content

Review the SDN controller configuration to determine if it is configured to enable reactive flow setup. 

If the SDN Controller is not configured to notify the forwarding device to either drop the packet or make an entry in the flow table for a received packet that does not match any flow table entries, this is a finding.

Fix Text

Configure the SDN controller to enable reactive flow setup so that the controller will notify a forwarding device to either drop the packet or make an entry in the flow table for a received packet that does not match any flow table entries.