← Back to IBM MQ Appliance V9.0 AS Security Technical Implementation Guide

V-255779

CAT III (Low)

The MQ Appliance messaging server must compare internal MQ Appliance messaging server clocks at least every 24 hours with an authoritative time source.

Rule ID

SV-255779r981685_rule

STIG

IBM MQ Appliance V9.0 AS Security Technical Implementation Guide

Version

V1R2

CCIs

CCI-001891

Discussion

Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events. Synchronization of system clocks is needed in order to correctly correlate the timing of events that occur across multiple systems. To meet this requirement, the organization will define an authoritative time source and have each system compare its internal clock at least every 24 hours.

Check Content

Log on as a privileged user to the WebGUI.
Select Network icon.
Interface NTP Service.

Verify: 
- NTP server destinations are configured.
- "Enable Administrative state" box is checked.

If "Enable Administrative state" is not checked or if no NTP servers are defined, this is a finding.

Fix Text

Log on as a privileged user to the WebGUI.
Select the  Network icon.
Interface NTP Service.

Ensure the box next to "Enable Administrative state" has a check mark.
Press the "Add" button to add multiple NTP servers.
Click the "Apply" button.

Add one or more additional NTP servers at least one of which is from a different geographic region.

Click "Save configuration".