SEL-2740S NDM Security Technical Implementation Guide

Version

V1R1

Release Date

May 6, 2019

SCAP Benchmark ID

SEL-2740S_NDM_STIG

Total Checks

13

Tags

other
CAT I: 1CAT II: 12CAT III: 0

This Security Technical Implementation Guide is published as a tool to improve the security of Department of Defense (DoD) information systems. The requirements are derived from the National Institute of Standards and Technology (NIST) 800-53 and related documents. Comments or proposed revisions to this document should be sent via email to the following address: disa.stig_spt@mail.mil.

Export CKLExport CSVExport JSON

Checks (13)

V-92291MEDIUMThe SEL-2740S must be configured to create log records for DoD-defined events.V-92293MEDIUMThe SEL-2740S must alert the ISSO and SA (at a minimum) in the event of an audit processing failure.V-92295MEDIUMThe SEL-2740S must be configured to send log data to a Syslog server or collected by another parent OTSDN Controller.V-92297MEDIUMThe SEL-2740S must be configured to compare internal information system clocks at least every 24 hours with an authoritative time server.V-92299MEDIUMThe SEL-2740S must be configured to synchronize internal system clocks with an authoritative time source.V-92301MEDIUMThe SEL-2740S must be configured to maintain internal system clocks with a backup authoritative time server.V-92303HIGHThe SEL-2740S must be adopted by OTSDN Controllers for secure communication identifiers and initial trust for configuration of remote maintenance and diagnostic communications.V-92305MEDIUMThe SEL-2740S must be configured to permit the maintenance and diagnostics communications to specified OTSDN Controller(s).V-92307MEDIUMThe SEL-2740S must be adopted by OTSDN Controller(s) and obtain its public key certificates from an appropriate certificate policy through an approved service provider.V-92309MEDIUMThe SEL-2740S must be configured to establish trust relationships with parent OTSDN Controller(s).V-92311MEDIUMThe SEL-2740S must be configured to send log data to a syslog server for the purpose of forwarding alerts to the administrators and the ISSO.V-94589MEDIUMThe SEL-2740S must authenticate Network Time Protocol sources using authentication that is cryptographically based.V-94591MEDIUMThe SEL-2740S must employ automated mechanisms to assist in the tracking of security incidents.